The following tables identify part numbers and provide brief descriptions of the SAN Volume Controller 2145-DH8 parts. Use the assembly index number to locate and identify the parts that are shown in Figure 1.
Figure Index | FRU Part Number | Quantity | Description |
---|---|---|---|
1 | 94Y6622 | 1 | Top cover assembly |
2 | 94Y6704 | 2 |
PCI Express riser card assembly
Each expansion slot might contain one of the optional adapters. There must be at least one Fibre Channel (FC) or one 10 gigabits-per-second (Gbps) Ethernet adapter in riser card assembly 1. |
3 | 01AC573 | 0-1 |
12 Gbps SAS adapter
This adapter connects the SAN Volume Controller 2145-DH8 to the SAN Volume Controller 2145-24F expansion enclosure. It is installed into PCI express expansion slot 3. |
4 | 31P1702 | 0-3 |
A 4-port 8 Gbps Fibre Channel (FC) adapter
ImportantIf the system is using alternative small form-factor pluggable (SFP) transceivers, replace the SFPs on the FRU part with the SFPs from the FC adapter that is being replaced.
|
31P1630 | 0-12 |
8 Gbps Shortwave small form-factor pluggable (SFP) transceiver
This SFP transceiver provides an auto-negotiating 2, 4, or 8 Gbps shortwave optical connection on a 8 Gbps FC adapter.
ImportantIt is possible that SFPs other than those that are shipped with the product are in use on the FC host bus adapter. It is a customer responsibility to obtain replacement parts for such SFPs. The FRU part number is shown as "Non-standard - supplied by customer" in the vital product data.
|
|
00RY004 | 0-4 |
2-port 16 Gbps FC host bus adapter
ImportantIf the system is using alternative SFPs, replace the SFPs on the FRU part with the SFPs from the FC adapter that is being replaced.
|
|
00WY983 | 0-4 |
4-port 16 Gbps FC adapter
Important
|
|
00RY190 | 0-16 |
16 Gbps Fibre Channel (FC) short-wave (SW) small form-factor pluggable (SFP) transceiver
This SFP transceiver provides an auto-negotiating 2, 4, 8 or 16 Gbps shortwave optical connection on a 16 Gbps FC adapter.
ImportantIt is possible that SFPs other than those that are shipped with the product are in use on the FC adapter. It is the customer responsibility to obtain replacement parts for such SFPs. The FRU part number is shown as
Non-standard - supplied by customerin the vital product data. |
|
01YM898 | 0 - 4 | 32 Gbps 4-port Fibre Channel (FC) adapter | |
01YM942 | 0 - 16 |
32 Gbps Fibre Channel (FC) short-wave (SW) small form-factor pluggable (SFP) transceiver
ImportantIt is possible that SFPs other than those that are shipped with the product are in use on the FC adapter. It is the customer responsibility to obtain replacement parts for such SFPs. The FRU part number is shown as
Non-standard - supplied by customerin the vital product data. |
|
02PX560 | 0 - 8 |
32 Gbps Fibre Channel (FC) long-wave (LW) small form-factor pluggable (SFP) transceiver
ImportantIt is possible that SFPs other than those that are shipped with the product are in use on the FC adapter. It is the customer responsibility to obtain replacement parts for such SFPs. The FRU part number is shown as
Non-standard - supplied by customerin the vital product data. |
|
00AR319 | 0-1 |
10 Gbps Ethernet adapter
This includes a 10 Gbps Ethernet adapter that provides connectivity for up to four 10 Gbps fiber optic Ethernet cables. These cables are used for Fibre Channel over Ethernet (FCoE) and for iSCSI communications. |
|
31P1549 | 0-4 | 10 Gbps Shortwave SFP small form-factor pluggable (SFP) transceiver. | |
00AR065 | 0-2 |
Compression accelerator
This option accelerates I/O between nodes and compressed volumes. The second microprocessor and eight memory modules must be installed. The compression accelerator can be installed only in PCI expansion slots 4 and 6. |
|
5 | 94Y6618 | 1-2 |
Heat sink
95 W heat sink for the microprocessor. When you replace this part, you need alcohol wipes and thermal grease. |
6 | 00Y2783 | 1-2 |
Microprocessor
Intel Xeon E5-2650V2, 2.60 GHz, 8 core, 20 MB cache, 95 W.
ImportantThis part is the microprocessor only. When replaced, you must also have alcohol wipes and thermal grease.
|
7 | 94Y7739 | 1-2 | Heat sink retention module |
8 | 00D5034 | 4-8 |
Memory module
8 GB, single-rank, 1.5 V, DDR3, 1866 MHz, RDIMM. Four memory modules are installed if there is one microprocessor. Eight memory modules are installed if two microprocessors are available. |
9 | 00AM209 | 1 |
System board
ImportantThis part is also called the planar, and is the system board only. When you replace this part, you must use the microprocessor, DIMMs, and CMOS battery from the system board that you are replacing.
|
33F8354 | 1 |
CMOS battery
3.0 V. This part maintains the system BIOS settings. |
|
10 | 94Y8114 or 94Y8116 | 2 |
Power supply unit
Two power units are shown in Figure 1. |
11 | 94Y6619 | 1 |
Safety cover
240 V AC. |
12 | 00AM393 | 1 |
Operator-information panel
This assembly includes the information panel that contains the power-control button and diagnostic LEDs. |
90Y4768 | 1 | Operator-information panel cable. | |
13 | 00KA089 | 1 | DVD bay EMC shield |
14 | 00AR186 | 1 | Tape bay EMC shield |
15 | 44T2248 | 6 | Drive-slot blank EMC filler assembly |
16 | 00WY584 | 1 | Bezel with node LEDs |
00NV626 | 1 |
Bezel overlay
This part fits over the bezel. |
|
17 | 01EJ624 | 2 |
Battery
The batteries provide temporary power to save the write cache and node status to disk if main power is lost. Two batteries are shown in Figure 1. |
18 | 90Y8878 | 2 |
Boot disk drive
300 GB, SAS, 2.5 inches. |
19 | 00RY001 | 1 |
Battery backplane
This part manages the batteries and switches the node to battery power if main power is lost. |
81Y6674 | 2 |
SAS signal cable
820 mm, SAS. Connects the disk drive backplane to the system board. |
|
81Y6773 | 1 | Disk drive backplane configuration cable. | |
20 | 46W9187 | 1 |
Disk drive backplane
Hot-swappable, SAS, 2.5 inches. |
00FK347 | 1 |
Disk and battery backplane power and emergency power off warning (EPOW) cable
The EPOW cable is a Y cable; one end connects to the system board and the other two ends connect to the disk drive backplane and the battery backplane. |
|
00AR497 | 1 |
Battery backplane power cable
Supplied with dummy DIMMs. |
|
00RY335 | 1 | Battery backplane voltage sense cable | |
00AR499 | 1 | Battery backplane low-pin count (LPC) cable | |
00AR496 | 1 |
Battery backplane LPC cable converter with clip
This connects the battery backplane LPC cable to the system board. |
|
21 | 00AM212 | 1 | Fan cage |
22 | 94Y6620 | 3-4 |
Fan assembly
This part is used in each of the 4 fan positions. Four assemblies are shown in Figure 1. |
23 | 94Y6736 | 0-1 |
Fan blank
This part is used in place of fan 4 when only one microprocessor is installed. |
24 | 94Y6624 | 1 | Airflow baffle |
FRU part number | Description |
---|---|
00D3010 | Bezel screws |
39M5376 | 2.0 m jumper cable |
39M5700 | 5 m FC cable |
39M5701 | 25 m FC cable |
41Y9292 | Thermal grease |
46X0581 | Ethernet Cat 5E cable |
49Y5356 | EIA set kit |
59P4739 | Alcohol wipes |
69Y5787 | Power paddle card |
81Y6770 | USB cable |
81Y6775 | VGA cable |
90Y6464 | Cable management arm assembly (2U) |
94Y6629 | USB module |
94Y6719 | Support rails |
94Y6746 | Miscellaneous parts kit |
94Y9955 | Microprocessor installation tool |
FRU Part Number | Description | Feature Code |
---|---|---|
00RY191 |
16 Gbps Long-wave SFP transceiver (pack of 2).
ImportantIt is possible that SFP transceivers other than those shipped with the product are in use on the FC host bus adapter. It is the customer responsibility to obtain replacement parts for the SFP transceiver. The FRU part number is shown as
Non standard - supplied by customerin the vital product data. |
ACHU |
31P1658 |
8 Gbps Long-wave SFP transceiver.
ImportantIt is possible that SFP transceivers other than those shipped with the product are in use on the FC host bus adapter. It is a customer responsibility to obtain replacement parts for the SFP transceiver. The FRU part number is shown as "Non standard - supplied by customer" in the vital product data.
|
AH1T |