服务热线
15920845984
Description | Part number | Feature code | Maximum quantity per one controller unit |
---|---|---|---|
Host connectivity card options | |||
6Gb SAS 4 Port Host Interface Card | 00MJ093 | ACHJ | 2* |
8Gb FC 4 Port Host Interface Card | 00MJ095 | ACHK | 2* |
1Gb iSCSI 4 Port Host Interface Card | 00MJ097 | ACHL | 2* |
10Gb iSCSI - FCoE 2 Port Host Interface Card | 00MJ099 | ACHM | 2* |
SFP options for 8 Gb FC host interface card (ships with a pair of 8 Gb FC SW SFP transceivers) | |||
8Gb FC SW SFP Transceivers (Pair) | 00MJ103 | ACHS | 2** |
8Gb FC LW SFP Transceivers (Pair) | 00MJ105 | ACHT | 4*** |
Cable options for FC, FCoE, and 10 Gb iSCSI host connectivity (AC-powered models only) | |||
Lenovo 0.5m LC-LC OM3 MMF Cable | 00MN499 | ASR5 | 8 |
Lenovo 1m LC-LC OM3 MMF Cable | 00MN502 | ASR6 | 8 |
Lenovo 3m LC-LC OM3 MMF Cable | 00MN505 | ASR7 | 8 |
Lenovo 5m LC-LC OM3 MMF Cable | 00MN508 | ASR8 | 8 |
Lenovo 10m LC-LC OM3 MMF Cable | 00MN511 | ASR9 | 8 |
Lenovo 15m LC-LC OM3 MMF Cable | 00MN514 | ASRA | 8 |
Lenovo 25m LC-LC OM3 MMF Cable | 00MN517 | ASRB | 8 |
Lenovo 30m LC-LC OM3 MMF Cable | 00MN520 | ASRC | 8 |
Cable options for FC, FCoE, and 10 Gb iSCSI host connectivity (AC- and DC-powered models) | |||
1m Fiber Cable (LC) (FC only) | 00MJ168 | ACSJ | 8 |
5m Fiber Cable (LC) (FC only) | 00MJ170 | ACSK | 8 |
10m OM3 Fiber Cable (LC) | 00MJ174 | ACSS | 8 |
25m Fiber Cable (LC) (FC only) | 00MJ172 | ACSL | 8 |
SAS host connectivity cables - Mini-SAS HD (controller) to Mini-SAS (host) | |||
0.6m SAS Cable (mSAS HD to mSAS) | 00MJ162 | ACSA | 14 |
1.5m SAS Cable (mSAS HD to mSAS) | 00MJ163 | ACSB | 14 |
3m SAS Cable (mSAS HD to mSAS) | 00MJ166 | ACSC | 14 |
SAS host connectivity cables - Mini-SAS HD (controller) to Mini-SAS HD (host) | |||
0.6m SAS Cable (mSAS HD to mSAS HD) | 00MJ176 | ACTA | 14 |
1.5m SAS Cable (mSAS HD to mSAS HD) | 00MJ178 | ACTB | 14 |
3m SAS Cable (mSAS HD to mSAS HD) | 00MJ180 | ACTC | 14 |
* Up to one per node canister; both node canisters must have the same connectivity type.
** Up to one extra SW SFP module pair per 8 Gb FC host interface card in the node canister; both node canisters must have the same connectivity type.
*** Up to two LW SFP module pairs per 8 Gb FC host interface card in the node canister; both node canisters must have the same connectivity type. The second pair of LW SFP modules replaces the SW SFP modules that ship standard with the 8 Gb FC HIC.
The Storwize V3700 controller units provide 6 Gb SAS internal dual-port drive connectivity, and each controller unit also has two 6 Gb SAS x4 (Mini-SAS HD SFF-8644) ports (1 port per node canister) for 6 Gb SAS expansion unit connectivity.