服务热线
15920845984
CCIN | Failing Function Code | Description | Model, expansion unit, or unit type | Part number |
---|---|---|---|---|
2748 |
Storage IOA
|
All |
|
|
2749 | Storage IOA (external removable media) | All | 04N2296** | |
2757 |
Storage IOA
|
9405-520, 9406-520, 9406-570, 9406-595, 9411-100 |
|
|
2763 |
Storage IOA
|
9111-285, 9115-505, 9110-510, 9110-51A, 9131-52A, 9405-520, 9406-520, 9111-520, 9133-55A, 9113-550, 9116-561, 9117-570, 7311-D11, 7311-D20, 9411-100, 9406-570 |
|
|
2765 | 447 | 2 GB fibre channel adapter for 64-bit PCI bus | All | 80P4384** |
2766 | Fibre Channel IOA (for disk drive attachment only) | All | 80P4385** | |
2767 | Storage IOA | All | 04N2304** | |
2778 |
Storage IOA
|
9111-285, 9115-505, 9110-510, 9110-51A, 9131-52A, 9405-520, 9406-520, 9111-520, 9133-55A, 9113-550, 9116-561, 9117-570, 7311-D11, 7311-D20, 9411-100, 9406-570 |
|
|
2780 |
Storage IOA
|
All |
|
|
2782 |
Storage IOA
|
9111-285, 9115-505, 9110-510, 9110-51A, 9131-52A, 9405-520, 9406-520, 9111-520, 9133-55A, 9113-550, 9116-561, 9117-570, 7311-D11, 7311-D20, 9411-100, 9406-570 |
|
|
2787 | Fibre Channel IOA (for disk drive attachment only) | All | 80P6417** | |
280D | Fibre Channel IOA (for removable media attachment only) | All |
03N5014* 03N5005** |
|
280E | Disk controller | All | 03N5016* | |
2847 | Fibre Channel IOP | All | 39J2894* | |
5702 | Storage IOA | All | 97P6513** | |
5703 |
Storage IOA
|
9111-285, 9115-505, 9110-510, 9110-51A, 9131-52A, 9405-520, 9406-520, 9111-520, 9133-55A, 9113-550, 9116-561, 9117-570, 7311-D11, 7311-D20, 9411-100, 9406-570 |
|
|
5704 | Fibre Channel IOA (for removable media attachment only) | All | 80P6416** | |
5708 |
Auxiliary cache adapter
|
All |
|
|
5709 | RAID enablement card | 9111-285, 9405-520, 9406-520, 9111-520, 9406-525, 9406-550, 9113-550 | 39J0149** | |
5709 | RAID enablement card | 9406-570, 9117-570 | 39J0148** | |
5709 | Battery pack | 9111-285, 9115-505, 9110-510, 9110-51A, 9131-52A, 9405-520, 9406-520, 9111-520, 9133-55A, 9113-550, 9116-561, 9117-570, 7311-D11, 7311-D20, 9411-100, 9406-570 |
42R5070* 44L0313** |
|
570B | Imbedded storage IOA | 515, 520, 525 550, 570 | Replace the system backplane (see Backplanes). | |
570C | Imbedded storage IOA | 570 | Replace the I/O backplane (see Backplanes). | |
571A | Storage IOA | 7037-A50, 7047-185, 9111-285, 9115-505, 9110-510, 9110-51A, 9131-52A, 9405-520, 9406-520, 9111-520, 9133-55A, 9406-550, 9113-550, 9116-561, 9406-570, 9117-570, 9406-595, 9407-515, 9406-525 |
42R4860* 39J4996** |
|
571B |
Storage IOA
|
7037-A50, 7047-185, 9110-510, 9110-51A, 9131-52A, 9405-520, 9406-520, 9111-520, 9133-55A, 9113-550, 9116-561, 9406-570, 9117-570, 9118-575, 9119-590, 9119-595, 9406-525, 9406-525 |
|
|
571E |
Storage IOA
|
All |
1. 42R5130* |
|
571F, 575B | 22E |
Combination storage (571F) and auxiliary cache (575B) IOA 1. Card 2. Cache battery pack |
9405-520, 9406-520, 9406-525, 9406-550, 9406-570, 9406-595, 9411-100 |
42R6578* 42R3965* |
573D | 2529 |
RAID enablement card 1. Card 2. Battery |
9111-285, 9110-51A, 9131-52A, 9405-520, 9406-520, 9111-520, 9133-55A, 9406-550, 9113-550, OpenPower 720, 9407-515, 9406-525 |
1. 39J5653* 39J3539** 2. 42R5070* 44L0313** |
573D |
RAID enablement card 1. Card 2. Battery |
9116-561, 9406-570, 9117-570 |
1. 39J5652* 39J3538** 2. 42R5070* 44L0313** |
|
574F | 2D07 |
PCI-X DDR auxiliary cache adapter
|
All |
1. 42R5133* |
* Designed to comply with RoHS requirement